RO System Water Filtration
RO System Includes:
* Feed Water Pump
* Pretreatment filter (according to your water analysis report choose the multi-media filter, activated carbon filter, soften system )
* PH dosing system
* Cartridge filter
* CIP clean system
* High pressure pump
* RO membrane
Description
1. We offer a wide range of industrial reverse osmosis Plants, according to We need for tap water, brackish water & sea water application. The production range starts from 100 LPH (Liter per hour) to 100 M3 per hour for 400 IBS to 45,000 TDS and reduce TDS @ 90-99% .
2. All our industrial reverse osmosis Plants are carefully customized and configured to suit the individual requirement of the output water, which varies from normal drinking application to the specific usage, such as food Processing, pharmaceuticals and boiler feeding requirement. This is done through an in depth and complete chemical analysis of the feed water available to us in specific location.
3. Reverse Osmosis has gained wide acceptance and popularity due to its simple operation and the ability to withstand variations in feed water quality.

Application
* Drinking water purification
* Water and wastewater purification
* Food industry
* Maple syrup production
* Hydrogen production
* Reef aquariums
* Window cleaning
FRQ
1. What information do I need to provide to get a quotation for a Hinada Industrial RO System?
To receive a suitable proposal, you need to provide: (1) source water quality, specifically the TDS level/Hardness, better have test report; (2) what’s output usage, the required treated water standards? ; (3) your local power voltage, Hz, and frequency; and (4) your required capacity per hour or per day. Hinada’s RO systems cover a production range from 100 LPH to 100 m³ per hour, handling TDS from 400 to 45,000 with a TDS reduction rate of 90–99%.
2. What are the key operating specifications of a Hinada Industrial RO System?
Key specifications include: recovery rate of 60–75%, RO salt rejection of ≥98.5%, operating temperature ≤50℃, operating pressure ≤20 Bar, and working pH range of 6.0–8.0. The membrane type is TFC (Thin Film Composite) with PA (Polyamide) material, configured in a spiral-wound, FRP-wrapped design. Maximum feed turbidity is ≤1.0 NTU, maximum SDI₁₅ is ≤5.0, and free chlorine concentration must be ≤0.1 ppm.
3. What pretreatment components are included in a Hinada Industrial RO System?
A standard Hinada Industrial RO System includes: a feed water pump, pretreatment filters (multi-media filter, activated carbon filter, and softener selected based on your water analysis report), anti-scaling dosing system, cartridge filter, CIP (Clean-in-Place) cleaning system, a high-pressure pump, and RO membranes. The pretreatment is critical for protecting the membrane against organic fouling, mineral scaling, and chemical degradation.
4. Why is my RO system’s permeate flow decreasing?
Low permeate flow is commonly caused by: (1) inlet pressure dropping below the standard value (typically below 0.15 MPa), resulting in insufficient driving force for the membrane elements; (2) membrane pore blockage after long-term operation, narrowing the water flow channels; or (3) inlet water temperature being too low (below 15℃), reducing water molecule activity. Recommended actions include checking the booster pump to maintain pressure at 0.15–0.25 MPa, replacing severely fouled membranes, and installing a feed water heater to keep water temperature in the optimal range of 20–25℃.
Benifits
* Hinada Process design of the whole RO System water filtration.
* Supply the completely RO plant
* Installation service
* Commissioning
* After-sales service
* Water treatment RO equipment
* Commercial industrial RO system
Package
The RO System Water Filtration will be packaged in Plywood case or in container.
Our Service
We are the manufacturer of UF Membrane / MBR Membrane / Water Filtration Equipment, we can offer according to your project requirement requirement, provide machine for tap water, brackish water & sea water application.
- Description:
-
Description
1. We offer a wide range of industrial reverse osmosis Plants, according to We need for tap water, brackish water & sea water application. The production range starts from 100 LPH (Liter per hour) to 100 M3 per hour for 400 IBS to 45,000 TDS and reduce TDS @ 90-99% .
2. All our industrial reverse osmosis Plants are carefully customized and configured to suit the individual requirement of the output water, which varies from normal drinking application to the specific usage, such as food Processing, pharmaceuticals and boiler feeding requirement. This is done through an in depth and complete chemical analysis of the feed water available to us in specific location.
3. Reverse Osmosis has gained wide acceptance and popularity due to its simple operation and the ability to withstand variations in feed water quality.

- Application
-
Application
* Drinking water purification
* Water and wastewater purification
* Food industry
* Maple syrup production
* Hydrogen production
* Reef aquariums
* Window cleaningFRQ
1. What information do I need to provide to get a quotation for a Hinada Industrial RO System?
To receive a suitable proposal, you need to provide: (1) source water quality, specifically the TDS level/Hardness, better have test report; (2) what’s output usage, the required treated water standards? ; (3) your local power voltage, Hz, and frequency; and (4) your required capacity per hour or per day. Hinada’s RO systems cover a production range from 100 LPH to 100 m³ per hour, handling TDS from 400 to 45,000 with a TDS reduction rate of 90–99%.
2. What are the key operating specifications of a Hinada Industrial RO System?
Key specifications include: recovery rate of 60–75%, RO salt rejection of ≥98.5%, operating temperature ≤50℃, operating pressure ≤20 Bar, and working pH range of 6.0–8.0. The membrane type is TFC (Thin Film Composite) with PA (Polyamide) material, configured in a spiral-wound, FRP-wrapped design. Maximum feed turbidity is ≤1.0 NTU, maximum SDI₁₅ is ≤5.0, and free chlorine concentration must be ≤0.1 ppm.
3. What pretreatment components are included in a Hinada Industrial RO System?
A standard Hinada Industrial RO System includes: a feed water pump, pretreatment filters (multi-media filter, activated carbon filter, and softener selected based on your water analysis report), anti-scaling dosing system, cartridge filter, CIP (Clean-in-Place) cleaning system, a high-pressure pump, and RO membranes. The pretreatment is critical for protecting the membrane against organic fouling, mineral scaling, and chemical degradation.
4. Why is my RO system’s permeate flow decreasing?
Low permeate flow is commonly caused by: (1) inlet pressure dropping below the standard value (typically below 0.15 MPa), resulting in insufficient driving force for the membrane elements; (2) membrane pore blockage after long-term operation, narrowing the water flow channels; or (3) inlet water temperature being too low (below 15℃), reducing water molecule activity. Recommended actions include checking the booster pump to maintain pressure at 0.15–0.25 MPa, replacing severely fouled membranes, and installing a feed water heater to keep water temperature in the optimal range of 20–25℃.
- Benefits
-
Benifits
* Hinada Process design of the whole RO System water filtration.
* Supply the completely RO plant
* Installation service
* Commissioning
* After-sales service
* Water treatment RO equipment
* Commercial industrial RO system - Packaging
-
Package
The RO System Water Filtration will be packaged in Plywood case or in container.
- Our Service
-